The PVA-FMP-AT fireman microphone panel is a specialized component of the PAVIRO system, designed for reliable and compliant operation in emergency situations. It includes a handheld microphone, rugged housing, and intuitive controls for use during fire alarms or other emergency events.
Key Features
-
Fireman Handheld Microphone:
- Handheld microphone with a non-latching side talk button for ease of use, even with gloves.
- Microphone activation interrupts ongoing announcements for immediate emergency communication.
-
User-Friendly Operation:
- 7 buttons, including 5 for predefined alarm announcements.
- LED indicators for fault and status monitoring.
-
Durable and Compliant Design:
- Non-flammable sheet steel housing with a lockable front door (EN 54‑11 compliant).
- Labeling and controls designed per ÖNORM F3033 standards.
-
Reliable Functionality:
- Buzzer, status LED indicators, and acknowledge/reset features ensure full situational awareness.
- All-clear button for post-emergency operations.
Certifications & Compliance
-
Emergency Standards:
- Austria: ÖNORM F3033.
-
Environmental Directive Compliance:
- Immunity: EN 50130-4.
- Emissions: EN 61000-6-3.
- Environment: EN 50581.
-
Conformity:
- CE (Europe).
Technical Specifications
Electrical
-
Power Supply:
- Nominal Voltage: 24 VDC.
- Voltage Range: 15–58 VDC.
-
Power Consumption:
- Idle Mode: 53 mA at 24 VDC.
- Alarm Mode: 75 mA at 24 VDC.
-
Audio Performance:
- Frequency Response: 200 Hz to 16,000 Hz (+0/-3 dB).
- Signal-to-Noise Ratio: ≥ 60 dB.
- NF Output Levels:
- Nominal: +6 dBu.
- Maximum: +12 dBu.
- Microphone Input Level: Maximum -21 dBu.
Microphone Specifications
- Type: Handheld.
- Polar Pattern: Omnidirectional.
- Frequency Response: 280 Hz to 14,000 Hz.
- Sensitivity: 3.1 mV/Pa ± 4 dB.
Environmental
- Operating Temperature: -5 °C to +40 °C.
- Storage/Transport Temperature: -10 °C to +60 °C.
Mechanical
- Dimensions (W × H × D): 200 mm × 300 mm × 110 mm.
- Material: Non-flammable sheet steel.
- Color: Red (RAL 3000).
- Weight: 3.8 kg.
- Ingress Protection: IP30 (DIN 40050).
Parts Included
- 1 × PVA-FMP-AT Fireman Microphone Panel.
- 2 × Door lock keys (EN 54‑11 compliant).
- 1 × Installation and operation manual.
- 1 × Important safety instructions.
Applications
The PVA-FMP-AT is designed for fire alarm and emergency communication systems, ensuring reliable operation in high-stress situations. It is suitable for fire alarm control rooms, evacuation zones, and other critical areas requiring voice announcements during emergencies.

BOSCH
Bosch - PAVIRO - PVA-FMP-AT Fireman microphone panel
The PVA-FMP-AT fireman microphone panel is a specialized component of the PAVIRO system, designed for reliable and compliant operation in emergency situations. It includes a handheld microphone, rugged housing, and intuitive controls for use during fire alarms or other emergency events.
Key Features
-
Fireman Handheld Microphone:
- Handheld microphone with a non-latching side talk button for ease of use, even with gloves.
- Microphone activation interrupts ongoing announcements for immediate emergency communication.
-
User-Friendly Operation:
- 7 buttons, including 5 for predefined alarm announcements.
- LED indicators for fault and status monitoring.
-
Durable and Compliant Design:
- Non-flammable sheet steel housing with a lockable front door (EN 54‑11 compliant).
- Labeling and controls designed per ÖNORM F3033 standards.
-
Reliable Functionality:
- Buzzer, status LED indicators, and acknowledge/reset features ensure full situational awareness.
- All-clear button for post-emergency operations.
Certifications & Compliance
-
Emergency Standards:
- Austria: ÖNORM F3033.
-
Environmental Directive Compliance:
- Immunity: EN 50130-4.
- Emissions: EN 61000-6-3.
- Environment: EN 50581.
-
Conformity:
- CE (Europe).
Technical Specifications
Electrical
-
Power Supply:
- Nominal Voltage: 24 VDC.
- Voltage Range: 15–58 VDC.
-
Power Consumption:
- Idle Mode: 53 mA at 24 VDC.
- Alarm Mode: 75 mA at 24 VDC.
-
Audio Performance:
- Frequency Response: 200 Hz to 16,000 Hz (+0/-3 dB).
- Signal-to-Noise Ratio: ≥ 60 dB.
- NF Output Levels:
- Nominal: +6 dBu.
- Maximum: +12 dBu.
- Microphone Input Level: Maximum -21 dBu.
Microphone Specifications
- Type: Handheld.
- Polar Pattern: Omnidirectional.
- Frequency Response: 280 Hz to 14,000 Hz.
- Sensitivity: 3.1 mV/Pa ± 4 dB.
Environmental
- Operating Temperature: -5 °C to +40 °C.
- Storage/Transport Temperature: -10 °C to +60 °C.
Mechanical
- Dimensions (W × H × D): 200 mm × 300 mm × 110 mm.
- Material: Non-flammable sheet steel.
- Color: Red (RAL 3000).
- Weight: 3.8 kg.
- Ingress Protection: IP30 (DIN 40050).
Parts Included
- 1 × PVA-FMP-AT Fireman Microphone Panel.
- 2 × Door lock keys (EN 54‑11 compliant).
- 1 × Installation and operation manual.
- 1 × Important safety instructions.
Applications
The PVA-FMP-AT is designed for fire alarm and emergency communication systems, ensuring reliable operation in high-stress situations. It is suitable for fire alarm control rooms, evacuation zones, and other critical areas requiring voice announcements during emergencies.